Reference for Win32_UninterruptiblePowerSupply
|
|
Category (Kategorie): Batteries and Power Supplies
Description (Beschreibung): The Win32_UninterruptiblePowerSupply WMI class represents the capabilities and management capacity of an uninterruptible power supply (UPS). The properties of the UPS device indicate when incoming power is trimmed or boosted, and the aggregated information of the batteries, generators, and so on, that comprise the device. These individual components (for example, multiple batteries) can also be independently modeled and associated with the UPS.
Availability (Verfügbarkeit):
Properties (Attribute): Item | Server 2003 | XP Pro | Windows 2000 | NT 4.0 | Windows 98 | ActiveInputVoltage | Yes | Yes | Yes | Yes | Yes | Availability | Yes | Yes | Yes | Yes | Yes | BatteryInstalled | Yes | Yes | Yes | Yes | Yes | CanTurnOffRemotely | Yes | Yes | Yes | Yes | Yes | Caption | Yes | Yes | Yes | Yes | Yes | CommandFile | Yes | Yes | Yes | Yes | Yes | ConfigManagerErrorCode | Yes | Yes | Yes | Yes | Yes | ConfigManagerUserConfig | Yes | Yes | Yes | Yes | Yes | CreationClassName | Yes | Yes | Yes | Yes | Yes | Description | Yes | Yes | Yes | Yes | Yes | DeviceID | Yes | Yes | Yes | Yes | Yes | ErrorCleared | Yes | Yes | Yes | Yes | Yes | ErrorDescription | Yes | Yes | Yes | Yes | Yes | EstimatedChargeRemaining | Yes | Yes | Yes | Yes | Yes | EstimatedRunTime | Yes | Yes | Yes | Yes | Yes | FirstMessageDelay | Yes | Yes | Yes | Yes | Yes | InstallDate | Yes | Yes | Yes | Yes | Yes | IsSwitchingSupply | Yes | Yes | Yes | Yes | Yes | LastErrorCode | Yes | Yes | Yes | Yes | Yes | LowBatterySignal | Yes | Yes | Yes | Yes | Yes | MessageInterval | Yes | Yes | Yes | Yes | Yes | Name | Yes | Yes | Yes | Yes | Yes | PNPDeviceID | Yes | Yes | Yes | Yes | Yes | PowerFailSignal | Yes | Yes | Yes | Yes | Yes | PowerManagementCapabilities | Yes | Yes | Yes | Yes | Yes | PowerManagementSupported | Yes | Yes | Yes | Yes | Yes | Range1InputFrequencyHigh | Yes | Yes | Yes | Yes | Yes | Range1InputFrequencyLow | Yes | Yes | Yes | Yes | Yes | Range1InputVoltageHigh | Yes | Yes | Yes | Yes | Yes | Range1InputVoltageLow | Yes | Yes | Yes | Yes | Yes | Range2InputFrequencyHigh | Yes | Yes | Yes | Yes | Yes | Range2InputFrequencyLow | Yes | Yes | Yes | Yes | Yes | Range2InputVoltageHigh | Yes | Yes | Yes | Yes | Yes | Range2InputVoltageLow | Yes | Yes | Yes | Yes | Yes | RemainingCapacityStatus | Yes | Yes | Yes | Yes | Yes | Status | Yes | Yes | Yes | Yes | Yes | StatusInfo | Yes | Yes | Yes | Yes | Yes | SystemCreationClassName | Yes | Yes | Yes | Yes | Yes | SystemName | Yes | Yes | Yes | Yes | Yes | TimeOnBackup | Yes | Yes | Yes | Yes | Yes | TotalOutputPower | Yes | Yes | Yes | Yes | Yes | TypeOfRangeSwitching | Yes | Yes | Yes | Yes | Yes | UPSPort | Yes | Yes | Yes | Yes | Yes |
Methods (Methoden): Item | Server 2003 | XP Pro | Windows 2000 | NT 4.0 | Windows 98 | Reset | Yes | Yes | Yes | Yes | Yes | SetPowerState | Yes | Yes | Yes | Yes | Yes |
Sample Code (Beispiel):
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_UninterruptiblePowerSupply")
For Each objItem in colItems
Wscript.Echo "Caption: " & objItem.Caption
Next
Links:
Link zur Original-Microsoft-Dokumentation
www.IT-Visions.de, (C) Dr. Holger Schwichtenberg
|